INTRODUCTION
The incorporation of new technologies such as ultrasound using J-Plasma (helium plasma) and MicroAire (power assited liposuction) has facilitated liposculpture procedures, resulting in greater patient satisfaction and benefits 1,2; moreover, these technologies are associated with low complications, as described so far. This case is the fourth description of pneumomediastinum associated with the use of the Renuvion® (J-Plasma) technology, following liposuction for fat removal from the arms and thighs 3-5.
CASE REPORT
A 52-year-old female patient with no prior history of disease who underwent conventional liposuction of arms and lateral aspect of the thighs after tumescent solution infiltration (a mix of crystalloid plus 2 cm3 of epinephrine [2:1.000]). After removing approximately 7,000 cm3 of fat, skin tightening was performed using the Renuvion J-Plasma® technology. For the procedure, the generator was set at 80% power and helium flow at 2 liters per minute (L/min); the intervened body areas were treated on average with 6 repetitions each. In the immediate postoperative period the patient recovered well and was discharged from the hospital on the same day.
Four days after the surgical procedure, the patient presented to the emergency service complaining of one day of symptoms consisting of dyspnea, adynamia, headache, chills and generalized pain. Vital signs at presentation showed increased heart rate and temperature (blood pressure: 124/61 mm Hg; heart rate: 97 bpm; respiratory rate: 22 bpm; temperature: 37,9 °C). Findings on physical examination included painful facies, pale mucosas, and dressings on the intervened extremities showing signs of serosanguinous drainage but no signs of perilesional infection; crepitations were palpated over the sternal, supra and infraclavicular region, suggesting subcutaneous emphysema; the abdomen was soft and depressible on palpation, with no signs of peritoneal irritation. Paraclinical tests on admission showed severe anemia (hemoglobin 6.0 g/dL) (Table 1), associated with low cardiac output signs due to slow capillary filling, prompting transfusion of two units of red blood cells and the administration of procoagulants (tranexamic acid), oxygen supplementation through nasal cannula with 32% FiO2% (approximately) and central venous catheter placement. Due to signs of hypoperfusion in the first few hours, pulmonary artery CT angiography was performed, ruling out pulmonary embolism, but showing pneumomediastinum distributed along the neck and chest, and confirming generalized subcutaneous emphysema (Figure 1).
Test | On admission | 24-hour follow-up in ICU |
---|---|---|
Hb (g/dL) | 7.5 | 7.2 |
Plaquetas | 246,000 | 210,000 |
PO2 (mm Hg) | 100,4 | NR |
PCO2 (mm Hg) | 36.7 | NR |
Lactate (mmol/L) | 5.5 | 1.39 |
Creatinine (mg/dL) | 0.69 | 0.63 |
NR: no record.
Source: Authors.
The patient was assessed by the Thoracic Surgery and Plastic Surgery services which indicated clinical observation and monitoring in the intensive care unit, with no need for additional surgical interventions.
Because of increased temperature on admission, empirical antibiotic coverage was initiated with intravenous (IV) administration of piperacillin tazobactam 4.5 g every 6 hours + vancomycin 1 g IV every 12 hours. Initial blood cultures came back negative four days later, leading to discontinuation of antimicrobial therapy after 96 hours.
Intensive care monitoring was carried out during 48 hours, allowing to confirm dyspnea resolution and hemodynamic stability during the observation period. The follow-up chest X-ray showed subcutaneous emphysema along the chest wall and neck, with no significant changes on follow-up (Figure 2). Given a satisfactory clinical course, the patient was discharged after five days of observation.
DISCUSSION
Plasma-based devices have been used since the 1990s with the aim of heating and tightening collagen in the subdermal space in order to improve skin laxity 5. The J-Plasma/Renuvion® uses helium to allow for easy ionization under low power, creating a steady and accurate output to achieve subdermal coagulation and effective soft tissue shrinkage. The tissue around the treatment area remains at a lower temperature, allowing for rapid cooling and immediate soft tissue shrinkage without unnecessarily heating the entire dermal thickness 6.
The use of technologies such as the J-Plasma/Renuvion® is relatively recent. The UnitedStates Food andDrug Administration (FDA) analyzed the technology and, on July 15, 2022, approved (K191542) a helium-based plasma device (Renuvion®; Apyx Medical Corporation, Clearwater, FL) for soft tissue cutting, coagulation and ablation, and authorization 510(k) was granted for the use of Renuvion® in subcutaneous dermatological and esthetic procedures to improve the appearance of loose skin in the neck and submental region. In 2023, the FDA approved Renuvion®/J-Plasma for procedures designed to improve skin appearance by means of dermal rejuvenation or skin tightening 7. Given the recent approval by the FDA, the use of this therapy in the clinical setting may still be infrequent and hence the paucity of reported adverse events, with subcutaneous emphysema 8) and pneumomediastinum being among the most noteworthy. These complications have been found after the use of J-Plasma, and described as subcutaneous emphysema, usually involving the neck, chest and, in some cases, the abdomen, with no fatal outcomes reported 3-5. This case is the fourth description in the literature of pneumomediastinum associated with the use of J-Plasma technologies after a cosmetic procedure 3-5. In this case, J-Plasma/Renuvion® was used in accordance with the standards suggested by the device guideline, applying 80% power and 2 L/ min flow, with 6 repetitions in each area (the helium-based radio frequency device guideline is based on the number of times the surgeon uses de handpiece to deliver energy to the treatment area. The recommended technique is to treat 1-1.5 cm of tissue per second, with retrograde activation in device settings of 60-80% power and helium flow within a range of 1.5-3 liters per minute) 7.
The subcutaneous emphysema and pneumomediastinum documented in this case are not easily explained in the light of the classic mechanisms that give rise to these complications - infection, visceral perforation or spontaneous alveolar rupture 4. Therefore, in this case, the etiology could be attributed to an excess of helium, the mechanism by which the device operates 3,4, possible together with a low conversion from gas to plasma in the generator.
As for the clinical presentation, similar to other reported cases, subcutaneous emphysema in the neck and anterior chest wall was described 3-5. Dyspnea, on the other hand, has been described as a frequent symptom associated with pericardial and/or mediastinal gas extension 5. However, the diagnosis was established while looking for potential pulmonary embolism - a more frequent diagnosis 9 - in a patient with risk factors and a consistent clinical picture in whom pulmonary CT angiography revealed pneumomediastinum as an incidental finding that explained the presence of dyspnea. The other symptoms such as asthenia, adynamia and headache could be explained by the drop in hemoglobin (Hb), believed to be the result of blood loss during the intra and postoperative periods. The rise in temperature prompted blood cultures and clinical exam, which ruled out a suspected infection.
Treatment of subcutaneous emphysema is usually conservative, focused on early identification and removal of the gas source, after ruling out a pneumothorax. Clinical observation is often required with the patient breathing ambient air o receiving an FiO2 close to 100% in order to accelerate gas diffusion. The use of hyperbaric oxygen has been reported in one case, with similar good outcomes and fast recovery 5. In this case, the patient was managed conservatively with oxygen therapy through nasal cannula and 32% FiO2 (approximately) with a good response and early discharge 96 hours after admission.