SciELO - Scientific Electronic Library Online

 
vol.21 issue2EFFECT OF STORAGE OF HOT DRIED CAPE GOOSEBERRY ADDED WITH PHYSIOLOGICALLY ACTIVE COMPONENTS BY VACUUM IMPREGANTIONANTIMICROBIAL AND ANTIOXIDANT CAPACITY OF ANDEAN TUBERS (Tropaeolum tuberosum y Ullucus tuberosus) author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Revista U.D.C.A Actualidad & Divulgación Científica

Print version ISSN 0123-4226

Abstract

CANO SUAREZ, Harold F.; CIRO VELASQUEZ, Héctor J.  and  ARANGO TOBON, Julio C.. EFFECT OF DRYING AND MECHANICAL PRE-DRYING PREVIOUS TO STORAGE IN THE QUALITY OF COFFEE GRAIN (Coffea arabica L.). rev.udcaactual.divulg.cient. [online]. 2018, vol.21, n.2, pp.439-448. ISSN 0123-4226.  https://doi.org/10.31910/rudca.v21.n2.2018.1068.

The aim of this study was to evaluate the effect of drying and pre-drying conditions of samples of parchment coffee stored during 6 months under controlled conditions of relative humidity of 70% and temperature of 25°C quantifying the Electrical Conductivity (EC), Potassium Leaching (KL) and Fatty Acidity (FA) of the grain. The coffee drying consisted on combined processes using air temperatures of 50°C and 60°C and two periods of 4 and 8 hours in the mechanical pre-drying and subsequently taken to commercial moisture content under patio drying, and two control treatments consisting of complete mechanical drying and complete solar drying. The results of the tests showed the following values: 6.35 - 16.34 µSm cm-1 / g DM (EC), 2.0 - 4.45ppm / g DM (KL) and 0.76 - 1.57mL KOH / 100g MS (FA), where the statistical analysis shows that there is no effect of the drying type on the studied variables. However, the highest accumulated averages in the storage time were observed for the complete mechanical drying. The values did not show deterioration of the cellular structure attributed to the frame of reference of drying with high temperature or prolonged storage. The tests of Electrical Conductivity (EC) and Fatty Acidity (FA) shows sensitivity to the storage time while the Potassium Leaching (KL) test did not constitute an indicator of grain deterioration attributable to thermomechanical stress or storage time.

Keywords : wet parchment coffee; dehydration; silo dryer; shelf life; coffee quality.

        · abstract in Spanish     · text in Spanish     · Spanish ( pdf )