SciELO - Scientific Electronic Library Online

 
vol.49 issue2Legal regime of medical prescriptions in Spain and Iberoamerica author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Revista Colombiana de Ciencias Químico - Farmacéuticas

Print version ISSN 0034-7418On-line version ISSN 1909-6356

Abstract

ROLL FEIJO, Adriane Lettnin; HELLWIG, Fernanda Macke; PAIM, Clésio Soldateli  and  MALESUIK, Marcelo Donadel. Forced degradation studies and stability-indicating liquid chromatography method for determination of tirofiban hydrochloride and synthetic impurities. Rev. colomb. cienc. quim. farm. [online]. 2020, vol.49, n.2, pp.509-522.  Epub Nov 23, 2020. ISSN 0034-7418.  https://doi.org/10.15446/rcciquifa.v49n2.89926.

This study aimed to develop and validate a stability-indicating liquid chromatography method for the determination of tirofiban hydrochloride and two synthetic impurities (impurity A and impurity C). The method utilizes a RP-18 column (250 mm x 4.6 mm; 5 µm) with the PDA detector for quantitation. A mixture of triethylamine 0.1% (acidified to pH 5.5 with phosphoric acid) and acetonitrile was used as the mobile phase at a flow rate of 1 mL min-1 with gradient elution. The method presented satisfactory linearity, precision, accuracy and robustness, as well as low limits of detection and quantification, which demonstrate sensitivity in the determination of tirofiban and impurities A and C. It was selective for the determination of the drug and impurities analysed, without interference of the degradation products generated under forced conditions, demonstrating the stability-indicating capacity of the proposed method. Tirofiban showed to be practically stable to oxidative (30% H2O2 for 24 h) and thermal (75 °C for 24 h) conditions, but presented degradation to UVA light and acid hydrolysis, obeying the first order kinetics for both. In this way, it can be used as a stability-indicating method in the quality control of the raw material of tirofiban hydrochloride, as well as of the finished product. The obtained results demonstrate the importance of deepening the studies in this area, to guarantee the quality of commercialized pharmaceutical products.

Keywords : Degradation products; HPLC; impurities; tirofiban; stability.

        · abstract in Portuguese     · text in English     · English ( pdf )