SciELO - Scientific Electronic Library Online

 
vol.16 issue1EVALUATION OF THE DIAGNOSTIC PRECISION OF FINE NEEDLE PUNCTURE ASPIRATION IN PATIENTS WITH THYROID NODULEEPIDEMIOLOGICAL SITUATION OF POISSONING WITH CHEMICAL SUBSTANCES IN THE DEPARTMENT OF META-COLOMBIA, PERIOD 2009-2014 author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Biosalud

Print version ISSN 1657-9550

Abstract

SIMANCAS PALLARES, Miguel  and  AREVALO TOVAR, Luisa. PERFORMANCE OF FOUR STATISTICAL METHODS FOR THE ASSESSMENT OF TEST RE-TEST RELIABILITY OF CONTINUOUS VARIABLES IN A SAMPLE. Biosalud [online]. 2017, vol.16, n.1, pp.19-29. ISSN 1657-9550.  https://doi.org/10.17151/biosa.2017.16.1.4.

Objective: To compare the performance of four statistical tests in continuous variables test/retest reliability assessment. Methods: Statistical simulation study developed in the framework of an in vitro diagnostic test study including 120 teeth which met the inclusion criteria. Each tooth was positioned in a standardization device and was taken two digital x-rays (T0 and T1) in which we assessed tooth-length. Data were analyzed with descriptive statistics and then a statistical comparison was done with paired Student's "t" test, intraclass correlation coefficient, Pearson correlation coefficient and Lin's concordance correlation coefficient in Stata v.13.2 for Windows (StataCorp., TX., USA). Results: The average dental length for T0 was 21.15 mm and for T1 21.07 mm. Student's "t" test revealed an average difference of 0.089 (P=0.00). The intraclass correlation coefficient 0.877 (95% CI: 0.43 - 0.98), Pearson's productmoment correlation coefficient 0.93, and Lin's concordance correlation coefficient 0.93 (95% CI: 0.908 - 0.956). Conclusions: Selection of a statistical test for test/re-test reliability assessment should be made having in mind the research objectives in any context and the possibility of each method for error assessment. Thus, a method that currently complies with this essential requirement is Lin's concordance correlation coefficient, which is recommended for future test re-test research studies.

Keywords : reproducibility of results; statistics and numerical data; error; hypothesis-testing.

        · abstract in Spanish     · text in Spanish     · Spanish ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License