SciELO - Scientific Electronic Library Online

 
vol.16 issue3Retrospective analysis of the causes of condemnations of carcasses and viscera of cattle slaughtered in slaughterhouses in the Northern Region of the Eastern Amazon author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


CES Medicina Veterinaria y Zootecnia

On-line version ISSN 1900-9607

Abstract

MURILLO, Javier D.; ROBLEDO, Sara M.; MONTANO, Jaime  and  ACEVEDO, Sandra P.. Variation of intraocular pressure comparing rebound (TONOVET Plus®) and applanation (TONO-PEN VET®) tonometry in New Zealand rabbits treated with Amlodipine®. Ces. Med. Vet. Zootec. [online]. 2021, vol.16, n.3, pp.10-27.  Epub May 04, 2022. ISSN 1900-9607.  https://doi.org/10.21615/cesmvz.6319.

Rabbits have played an important role in ophthalmological research processes, however in the environment there has been a deficiency of sensitive equipment in measurement of intraocular pressure for this species. To compare intraocular pressure (IOP) measured with rebound (TONOVET Plus®) and applanation (TONO-PEN VET®) tonometry in healthy New Zealand rabbits treated with Amlodipine. Twelve healthy male New Zealand white rabbits, 5 months old; two groups with 6 individuals were used in this study. The experimental group was given Amlodipine® at a dose of 5 mg/kg, once a day for a month. Blood pressure and intraocular pressure were measurement before treatment and 6 h after treatment in a period of one month. A trend is noted where the group of animals treated with amlodipine® presents lower values than the control group, both in systolic and diastolic pressure. The systolic pressure of the control group showed an average of 116.5 ± 7.9 mmHg and 117.4 ± 8.9 mmHg and the treatment group showed an average of 113.6 ± 7.9 mmHg and 111.8 ± 10.0 mmHg (pretreatment and posttreatment respectively). Tonometry: the values obtained using the TONOVET Plus® (19 ± 3 mmHg) are on average higher than the values obtained using the TONO-PEN VET® (17 ± 3 mmHg). It was possible to demonstrate the relationship between systemic blood pressure and intraocular pressure in New Zealand white rabbits. Rebound tonometry showed less variability in results than applanation tonometry. This study confirmed that both tonometers are reliable for measuring IOP in rabbits.

Keywords : glaucoma; hypertension; intraocular pressure; iridocorneal angle; tonometer; tonometry.

        · abstract in Spanish | Portuguese     · text in English     · English ( pdf )