SciELO - Scientific Electronic Library Online

 
vol.19 issue2FACTORS CONDITIONING THE HEALTHY NEWBORNS BREASTEEDING IN HOSPITAL UNIVERSITARIO CLÍNICA SAN RAFAEL (HUCSR)TIBIOCALCANEAL ARTHRODESIS WITH PHILOS PLATE: EXPERIENCE IN THE HOSPITAL MILITAR CENTRAL - JANUARY 2007 TO DECEMBER 2009 author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


Revista Med

Print version ISSN 0121-5256On-line version ISSN 1909-7700

Abstract

RODRIGUEZ, JAVIER et al. CONFIRMATION OF THE METHODOLOGY OF DIAGNOSTIC AID FOR THE CARDIAC DYNAMICS FOR CLINICAL APPLICATION DEVELOPED BASED ON THE PROBABILITY THEORY. rev.fac.med [online]. 2011, vol.19, n.2, pp.167-177. ISSN 0121-5256.

Starting from the probability theory and dynamic systems, a novel methodology of diagnostic aid for the Holter test was developed previously, based on the probability theory. The aim of this paper is to assess its diagnostic concordance in normal and acutely ill cases. Fifteen normal Holter tests and 100 with different cardiac pathologies from patients older than 20 years were taken. Cardiac rates ranges and number of beats per hour were determined and the probability of theses ranges was estimated. The obtained values were analyzed according to the diagnostic parameters established in the previously developed methodology in order to differentiate the normal status from the disease. Finally, sensitivity, specificity and Kappa coefficient of the physical mathematical evaluation with regard to the conventional diagnosis for normal and acutely ill cases were assessed. The Holter tests with acute disease showed between 6 and 13 ranges of frequencies, and the normal ones between 13 and 21 ranges. The maximum probability of beats per hour in normality presented four cases with probability less then or equal to 0.217 or higher than or equal to 0.304, while for acute disease all had values higher than or equal to 0.304. From among the Holter tests, 5 with acute disease and 2 normal presented a number of beats lower than 3.000. The sum of probabilities of the most probable frequencies was between 0.203 and 0.379 for the normal ones and between 0.333 and 0.652 for the Holter tests with acute pathologies. Sensitivity and specificity values were 100% and 73.3%, and the Kappa coefficient 0.86. It was confirmed that the methodology developed based on the probability theory reveals an autoorganization of the cardiac system which allows to differentiate between normality and acute disease and to evidence the evolution between both at the clinical level.

Keywords : Holter test; probability; diagnostic aid.

        · abstract in Spanish | Portuguese     · text in Spanish     · Spanish ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License