SciELO - Scientific Electronic Library Online

 
vol.28 número2Prevalencia y factores asociados a la pediculosis niños de un jardín infantil de BogotáCaracterización de la cadena CD3 épsilon en el primate del nuevo mundo Aotus nancymaae índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • En proceso de indezaciónCitado por Google
  • No hay articulos similaresSimilares en SciELO
  • En proceso de indezaciónSimilares en Google

Compartir


Biomédica

versión impresa ISSN 0120-4157versión On-line ISSN 2590-7379

Resumen

MONTOYA, Astrid Elena et al. Concordance between thick blood smear, immunochromatography and polymerase chain reaction for malaria diagnosis. Biomédica [online]. 2008, vol.28, n.2, pp.252-261. ISSN 0120-4157.

Introduction. The rapid and effective diagnosis of malaria is the determining condition for an appropriate treatment and control of the disease. Objective. The sensitivity, specificity and the positive and negative predictive values were evaluated in cases of suspected malaria in Colombia in a comparison of a rapid diagnostic test. the PCR test and the thick blood smear-the traditional ‘gold standard.’ Materials and methods. A group of 100 patients with symptoms compatible with malaria, were included in the study. They were selected from the following Colombian regions: Urabá, Córdoba, lower Cauca, and relatively fewer from other malaria endemic areas of Colombia including the provinces of Valle, Chocó in the central west of Colombia and Vichada to the east. To each patient the following three tests were performed: the rapid OptiMAL® test, the PCR identification and the thick blood smear. The PCR amplified specific DNA sequences with primers designed to identify the genus Plasmodium, and the two species present in Colombia, P. falciparum and P. vivax. Results. The sensitivity of the rapid test versus the thick smear, for the diagnosis of both species of Plasmodium was 93.9% (95% CI: 87-100%) and the specificity was 94.3% (95% CI:.253 85-100%). The PCR compared with the thick smear showed a sensitivity of 100% (95% CI: 99-100%) and a specificity of 97.1% (95% CI: 90-100%). Conclusions. The sensitivity and specificity of the three tests did not present statistically significant differences. However, the thick blood smear was recommended as the standard test, mainly due to its low cost.

Palabras clave : Plasmodium; malaria [diagnosis]; diagnostic techniques and procedures; predictive value of tests; sensitivity and specificity; polymerase chain reaction.

        · resumen en Español     · texto en Español     · Español ( pdf )

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons