SciELO - Scientific Electronic Library Online

 
vol.19 número2Satisfacción y factores asociados en estudiantes usuarios del servicio odontológico de la institución prestadora de servicios de salud “IPS Universitaria” (Medellín)Cambios radiculares analizados con morfometría digital en incisivos superiores de pacientes jóvenes durante dieciocho meses de tratamiento ortodóncico índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • En proceso de indezaciónCitado por Google
  • No hay articulos similaresSimilares en SciELO
  • En proceso de indezaciónSimilares en Google

Compartir


Revista Facultad de Odontología Universidad de Antioquia

versión impresa ISSN 0121-246X

Resumen

BARGUIL DIAZ, Julia Lucía; CHICA ARRIETA, Edwin  y  LATORRE CORREA, Federico. Stress distribution in three types of posts with different lengths. Rev Fac Odontol Univ Antioq [online]. 2008, vol.19, n.2, pp.24-37. ISSN 0121-246X.

INTRODUCTION: the purpose of this study was to observe the stress distribution of teeth restored with intraradicular retention elements (posts) of different lengths, using the finite element analysis (FEA). METHODS: a tridimensional model of finite elements (4mm model with 34010 nodes and 9317 elements, 6 mm model with 36798 nodes and 10371 elements, 8 mm model with 38587 nodes and 11025 elements) of an upper central incisor is presented. The model of the dowel restored tooth involved trabecular bone, cortical bone, periodontal ligament, gingiva, root, gutta-percha, resin luting cement, posts, composite resin core (for prefabricated posts), metallic posts and metal ceramic crown. The dowels were fabricated with noble metal casting alloy, titanium and fiber glass. The dowels were cemented with resin luting cement. The variables included were modulus of elasticity, Poisson´s ratio, and post´s length (4, 6 and 8 mm). A load of 1N was applied to the crown at an angle of 45 degrees; von Mises stresses, main maximum and minimum stresses, maximum shear stress were then calculated. RESULTS: finite element analysis indicated that the distribution of stresses generated on the modeled tooth with different post lengths decreased significantly, this is in agreement with an inverse proportional relationship with the material´s modulus of elasticity. Stresses on the root were also reduced when post length was increased (4, 6 and 8 mm). CONCLUSIONS: within the limitations of this study, it was found that strong variations exist with respect to the post length in relation with the stress distribution on the dentin and in the post itself, being less the distribution of stresses in the dentin and in the posts with more length and with a higher modulus of elasticity.

Palabras clave : poste; longitud de poste; análisis de elementos finitos; post; post length; finite element analysis.

        · resumen en Español     · texto en Español     · Español ( pdf )

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons