SciELO - Scientific Electronic Library Online

 
vol.25 número2CREENCIAS, CONOCIMIENTOS Y PRÁCTICAS EN SALUD ORAL DE LA POBLACIÓN MAPUCHE-WILLICHE DE ISLA HUAPI, CHILECARACTERIZACIÓN DE LA DENTINA TRATADA ENDODÓNTICAMENTE índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • En proceso de indezaciónCitado por Google
  • No hay articulos similaresSimilares en SciELO
  • En proceso de indezaciónSimilares en Google

Compartir


Revista Facultad de Odontología Universidad de Antioquia

versión impresa ISSN 0121-246X

Resumen

BOTERO, Paola María et al. ASSESSMENT OF MOYERS AND TANAKA-JOHNSTON MIXED DENTITION ANALYSES FOR THE PREDICTION OF MESIODISTAL DIAMETERS OF UNERUPTED CANINES AND PREMOLARS. Rev Fac Odontol Univ Antioq [online]. 2014, vol.25, n.2, pp.359-371. ISSN 0121-246X.

INTRODUCTION: the objective of this study was to determine whether the methods of Moyers (M) percentile (p) 75, p85, p95 and Tanaka-Johnston (TJ), used in the prediction of the mesiodistal diameter of unerupted canines and premolars, either overestimate or underestimate their respective succedaneous diameter. METHODS: diagnostic technology assessment in 56 plaster models of schoolchildren from Medellin, with class I skeletal and permanent erupted incisors, canines, and bicuspids, with follow-ups from 6 to 12 years of age. The teeth mesiodistal diameter was measured by the predictive methods of Tanaka-Johnston and Moyers p75, p85, p95. The predicted and actual values were evaluated by means of related Student's t test and Wilcoxon test. These methods' reproducibility was calculated by intraclass correlation coefficient (ICC) (95% CI), and their level was calculated using Bland-Altman 95% limits. RESULTS: : in the upper arch, significant actual value differences were observed with the T-J and Mp95 measurements. In the lower arch, the values of all the methods were different to the actual value (p > 0.05), except Mp75. Reproducibility was higher in the upper arch with T-J, followed by Mp85; in the lower arch, Mp75 was the method with the best reproducibility, followed by Mp85. In the upper arch, T-J overestimates the actual measurement by 0,333 mm in average (95% CI 2,100;1,434), and in the lower arch Mp75 overestimates by 2,14 (95% CI-2,020;1,592). CONCLUSSION: the best predictive method for the upper arch is Tanaka-Johnston, and for the lower arch, Moyers at the 75th percentile; although both methods overestimate the actual value, they show adequate reproducibility.

Palabras clave : prediction; reproducibility; unerupted tooth.

        · resumen en Español     · texto en Español | Inglés     · Español ( pdf )