SciELO - Scientific Electronic Library Online

 
vol.27 número2EVALUACIÓN DE LA RESISTENCIA ADHESIVA MEDIANTE LA PRUEBA DE DESALOJO EN POSTES DE FIBRA DE VIDRIO CEMENTADOS EN DIENTES NATURALES USANDO DIFERENTES PROTOCOLOS DE CEMENTACIÓNDESCRIPCIÓN DE LOS CAMBIOS MACROSCÓPICOS DE DISCOS DE RESINA COMPUESTA SOMETIDOS A ALTAS TEMPERATURAS CON FINES FORENSES índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

Links relacionados

  • En proceso de indezaciónCitado por Google
  • No hay articulos similaresSimilares en SciELO
  • En proceso de indezaciónSimilares en Google

Compartir


Revista Facultad de Odontología Universidad de Antioquia

versión impresa ISSN 0121-246X

Resumen

ZULUAGA, Juliana; GIRALDO, José Fernando  y  GARZON-RAYO, Herney. COMPARISON OF THE SHEAR BOND STRENGTH OF CERAMIC COATING AND ZIRCONIA SURFACE WITH AND WITHOUT MODIFICATIONS. Rev Fac Odontol Univ Antioq [online]. 2016, vol.27, n.2, pp.322-341. ISSN 0121-246X.  https://doi.org/10.17533/udea.rfo.v27n2a5.

Introduction:

currently, talking about highly resistant aesthetic dental restorations implies talking of yttrium-stabilized zirconium dioxide (Y-TZP) ceramic systems, which have become important due to their good mechanical and physical properties and high biocompatibility. One of the main complications of such restorations nowadays is ceramic coating delamination. It has been shown that the interface of both materials is the origin of failure because of poor bonding strength, mainly due to excessive internal tension in the coating material caused by a difference in the thermal expansion coefficients of both materials.

Methods:

15 zirconium blocks were randomly sorted out into 3 groups: one control group and two groups were the surface of bonding to the ceramic coating was modified by grinding with rounded diagonal and squared burs respectively. Once the samples were sintered, the ceramic coating was applied and shear bond strength tests were performed. A one-way analysis of variance (ANOVA) was conducted. The Tukey′s range test was used to compare the difference in results among groups.

Results:

the results in this study were very heterogeneous. The average shear bond strength values were 20.2 MPa ± 6.8 MPa for Group A; 5.87 MPa ± 4.87 Mpa for Group B, and 3.69 ± 2.68 MPa for Group C.

Conclusions:

it is not necessary to prepare the zirconium surface with mechanical grinding in order to improve shear bond strength in ceramic coatings.

Palabras clave : ceramics; zirconium; shear strength; delamination.

        · resumen en Español     · texto en Español | Inglés     · Inglés ( pdf )