Resumo
CARDONA HIDALGO, Julio César; GONZALEZ CARRENO, José Manuel e AVENDANO RUEDA, Julio César. Physicochemical properties of two epoxy resin-based sealants: Topseal® and AdSeal™. A comparative study. Rev Fac Odontol Univ Antioq [online]. 2019, vol.31, n.1, pp.68-76. ISSN 0121-246X. https://doi.org/10.17533/udea.rfo.v31n1-2a6.
Introduction:
a new epoxy resin-based root-canal sealer (AdSeal™) recently appeared on the market. The aim of this study was to evaluate the radiopacity, flow rate, and film thickness of this sealant compared to Topseal®.
Methods:
the tests were conducted in compliance with ISO 6876:2012 standards. To evaluate radiopacity, 5 discs of each sealant measuring 10 mm in diameter by 1 mm thick were crafted, comparing their radiographic density in mm of aluminum (Al). For flow rate analysis, 0.05 ml of sealant were placed between 2 glass plates under a weight of 120 g for 10 minutes. The diameters of the formed discs were measured with a calibrator and analyzed with the imageJ software. For film thickness analysis, the sealants were placed between 2 glass plates, applying a load of 150N with a universal testing machine (AGIS 5KN) for 10 minutes. Distance between the glass plates was measured using a stereomicroscope at three equidistant points.
Results:
Topseal® showed more radiopacity (Wilcoxon p < 0.05) and less flow rate than AdSeal™, with statistically significant differences (Anova p = 0.0001863). The film thickness values are above the limit allowed by standard 6876, possibly because of the methodology used in this study; however, no statistically significant difference was found between the sealants (Anova p = 0.4927).
Conclusions:
the radiopacity and flow rate of AdSeal™ and Topseal® sealants comply with the ISO 6876:2012 standard, but the film thickness values fail to meet the standard.
Palavras-chave : root canal sealer; flow rate; solubility; radiopacity; Topseal®; Ah plus®; AdSeal™.