Services on Demand
Journal
Article
Indicators
- Cited by SciELO
- Access statistics
Related links
- Cited by Google
- Similars in SciELO
- Similars in Google
Share
Colombian Journal of Anestesiology
Print version ISSN 0120-3347
Rev. colomb. anestesiol. vol.43 no.3 Bogotá July/Sept. 2015
Scientific and Technological Research
Analgesic efficacy of two concentrations of bupivacaine in women in labor: Randomized, controlled, triple blind clinical trial*
Eficacia analgésica entre dos concentraciones de Bupivacaína en mujeres en trabajo de parto. Ensayo clínico controlado aleatorizado triple ciego
Ricardo Rodríguez-Ramóna, Horacio Márquez-Gonzálezb,**, María Valeria Jiménez-Báezc, Ilse Cristina Iparrea-Ramosd
a Anesthesiologist, Hospital General de Zona Núm. 1, Instituto Mexicano del Seguro Social (IMSS), Campeche, Mexico
b Congenital Cardiopathy, Hospital de Cardiología, Centro Médico Nacional Siglo XXI, Ciudad de México D.F., México
c Research in Health and Health Provision Services, Delegación Estatal IMSS, Quintana Roo, Mexico
d Anesthesiologist, Hospital General Regional Núm. 17, IMSS, Quintana Roo, Mexico
* Please cite this article as: Rodríguez-Ramón R, Márquez-González H, Jiménez-Báez MV, Iparrea-Ramos IC. Eficacia analgésica entre dos concentraciones de Bupivacaína en mujeres en trabajo de parto. Ensayo clínico contralado aleatorizado triple ciego. Rev Colomb Anestesiol. 2015;43:179-185.
** Corresponding author at: Cardiopatías Congénitas, Hospital de Cardiología, Centro Médico Nacional Siglo XXI, Av. Cuauhtémoc 330, Col Doctores, C.P. 06720 Delegación Cuauhtémoc, Mexico City, Mexico.
E-mail address: horacioinvestigacion@hotmail.com (H. Márquez-González).
Article info
Article history: Received 17 February 2014 Accepted 17 February 2015 Available online 14 May 2015
Abstract
Introduction: Epidural analgesia is the safest and most effective method for the treatment of pain during childbirth. Epidural bupivacaine provides excellent analgesia for labor and remains the most widely used local anesthetic in obstetric anesthesia.
Objective: To evaluate the analgesic efficacy of two concentrations of bupivacaine in women in labor.
Methods: 114 patients in labor with term pregnancy were included in the study They were grouped randomly into two groups: patients who received bupivacaine at 0.125% (group A) and those who received 0.25% bupivacaine (group B). Patients in group A received a bolus injection of 10 ml of 0.125% bupivacaine. The patients in group B received a bolus of 10 ml bupivacaine 0.25%. Pain intensity according to VAS, blood pressure, heart rate, respiratory rate, and the degree of motorblock was assessed usingthe Bromage scale at different periods of time.
Results: Demographic characteristics and parity were compared with no statistically significant differences found. By comparing the values of the VAS measure at 0, 15, 30, 60 and 90 min, statistically significant differences in favor of the group with 0.25% bupivacaine were found with decreased pain perception after 30 min, p-value = 0.02. No differences in arterial pressure, heart rate and respiratory rate were found between the two groups.
Conclusion: The concentration of 0.25% bupivacaine has greater analgesic efficacy compared to 0.125% bupivacaine.
Keywords: Pain, Analgesia, Epidural, Bupivacaine, Labor obstetric.
Resumen
Introducción: La analgesia epidural es el método más seguro y eficaz para el tratamiento del dolor del parto. La Bupivacaína epidural proporciona una analgesia excelente para el parto y sigue siendo el anestésico local más utilizado en anestesia obstétrica.
Objetivo: Evaluarla eficacia analgésica entre dos concentraciones de Bupivacaína en mujeres en trabajo de parto.
Métodos: Se incluyeron 114 pacientes en trabajo de parto con embarazo de término. Se agruparon de forma aleatoria en dos grupos; pacientes que recibieron Bupivacaína al 0,125% (grupo A) y Bupivacaína al 0,25% (grupo B). Las pacientes del grupo A recibieron 10 ml de Bupivacaína al 0,125% en bolo. Las pacientes del grupo B recibieron 10 ml. de Bupivacaína al 0,25% en bolo. Se valoró la intensidad del dolor según la EVA, la presión arterial, frecuencia cardiaca, frecuencia respiratoria, el grado de bloqueo motor según la escala de Bromage en diferentes periodos de tiempo.
Resultados: Las características demográficas y de paridad se compararon, sin encontrar diferencias estadísticamente significativas. Al comparar los valores de la EVA medida en el minuto 0, 15, 30, 60 y 90 se encontraron diferencias estadísticamente significativas a favor del grupo con Bupivacaína al 0,25% con disminución de la percepción del dolor a partir del minuto 30, valor de p de 0,02. No se encontraron diferencias en la Presión Arterial, frecuencia cardiaca y frecuencia respiratoria entre ambos grupos.
Conclusión: La concentración de Bupivacaína al 0,25% mejora la eficacia analgésica en comparación con Bupivacaína al 0,125% en mujeres con trabajo de parto activo en 6 puntos a los a partir de los 60 minutos.
Palabras clave: Dolor, Analgesia, Epidural, Bupivacaina, Trabajo de parto.
Introduction
Pregnancy and childbirth are among the main reasons for care in hospitals around the world1. Pain during childbirth is conditioned by uterine contractility, which, in turn, is modulated by the secretion of endogenous catecholamines that activate beta-2 andrenergenic receptors2, causing the sensation of pain3.
Apart from being an unpleasant feeling, pain causes anguish and stress and limits cooperation during labor4, which may end in a reduction of fetoplacental flow leading to fetal acidosis.
The Visual Analog Scale (EVA) is a validated, subjective, and widely used tool to stratify the intensity of patient pain perception5.
In 1847, James Young Simpson was the first to use ether for analgesia during childbirth6. Currently, neuraxial analgesia is the most used procedure and its benefits are widely known7. The most used pharmaceuticals are ropivacaine and bupivacaine in different concentrations8,9. Bupivacaine is preferred because of its greater affinity for plasmatic proteins in pregnant women10, although cardiotoxic properties have been attributed to it since it affects calcium channels. However, in low concentrations, it is far from causing this cardiotoxic effect11.
There is scientific evidence regarding the use of low dosages of epidural analgesia compared to high doses or combined analgesia (p <0.05), such as the Comparative Obstetric Mobile Epidural Trial (COMET)12 from the Study Group in the United Kingdom. In this study, the results of different concentrations of anesthetics, like bupivacaine and ropivacaine, in epidural anesthesia during labor are compared, along with their relationship with the incidence of assisted vaginal childbirth, and their effect at a variety of doses. Nevertheless, there is no evidence of the efficacy for pain management of the use of different concentrations of a single local anesthetic, in this case bupivacaine, in patients undergoing childbirth13,14.
Objective
To assess the analgesic efficacy (VAS) between two concentrations of bupivacaine in women in labor.
Materials and methods
A randomized, triple blind clinical trial was conducted on pregnant patients in labor with registration in ClinicalTrials.gov (NCT02244086) and authorization from the Mexican Federal Commission for Health Risk Protection (Comisión Federal para la Protección Contra Riesgos Sanitarios - No. 2013-2301-21). The study took place in 2013 in Regional Hospital #17 of the Mexican Social Security Institute (IMSS) in the state of Quintana Roo, Mexico.
Patients were invited to participate with previously signed informed consent in physicians' offices once active labor was corroborated and before entering the Labor and Delivery room. Here, they were fully informed of the characteristics and risks of the study. The selection criteria were as follows: women with normal, to term pregnancies that requested obstetric analgesia with any number of gestations, a singleton pregnancy, in active labor (cervical dilation ≥4cm), with gestational age greater than 34 weeks, and an ASA (American Society of Anesthesiology) physical state of I or II. Patients who had problems like language barriers or allergies to local anesthetics were excluded. Also excluded were those women that presented any of the following situations in their last trimester: pregnancy induced hypertension, placenta previa, anomalies in the variety of fetal presentation, cephalopelvic disproportion, or hypertonic uterus. This was also the case for obstetric emergencies such as: severe preeclampsia, abruption of normally inserted placenta, fetal distress, or any alteration to the anatomy of the spinal column, or previous surgery that impede or limit the administration of epidural analgesia. Also excluded were those women who, despite having received epidural analgesia, finished the pregnancy with a cesarean section or prolonged labor, or those for whom there were failures in the epidural technique or related complications that merited three or more extra doses.
The groups were formed randomly and the triple blind trial was guaranteed for the patient (who was unaware of the concentration administered due to the similar appearance of the syringes and their content) and for the anesthesiologist (the bupivacaine was prepared by the researcher in a special area and delivered with a label that did not reveal the concentration but only the preparation with the letters A and B). An extra dose was prepared to be used in case extra medication was required, and for the data analyst the database was handed in and the lack of specificity guaranteed anonymity.
The result variables were as follows: pain perception as measured with VAS, heart rate, respiratory rate, sys-tolic/diastolic blood pressure, and unfavorable events at two different concentrations of bupivacaine (0.125 and 0.25%). Centimeters of cervical dilation pre- and post-anesthetics were obtained directly from the partogram.
During the progress of labor, if the patient showed a desire for obstetric analgesics, the gynecologist requested their administration. The appointed anesthesiologist would assess the general characteristics of the patient and decide whether or not she was a candidate for the procedure. The study was executed by residents and anesthesiologists with experience in more than 100 procedures of this nature and who were previously offered retraining on anesthetic technique in order to achieve standardization.
The main researcher created a coding sheet for the main information that was obtained from the Delivery Room admittance sheet. This information included: general information about the patient, age, number of gestations, history of previous analgesia, and complications during pregnancy. The VAS was measured with a standardized table at a time when the patient did not present contractions. The variables of heart rate, diastolic and systolic blood pressure, and respiratory rate were obtained by the anesthesiologist who applied the analgesia at different times. After the administration of analgesia, the variables of interest were measured initially, and at 15, 30, 60, and 90 min.
The sample size was determined with the mean difference formula15, considering a difference between the concentrations of bupivacaine of 3 points on the VAS at 30 min, and expecting a minimal decrease of 2 points at 30 min in both applications. A risk of0.05 and a statistical power of90% were accepted, calculating a sample size of 38 patients per group and forecasting 10% in losses, with a total estimated sample size of 84 women.
A partial analysis was conducted after obtaining % of the expected sample size to corroborate that the proposed treatment did not compromise the health of the child or the mother.
Statistical analysis
With the program SPSS version 20.00 for windows, and previous analysis of normality with the Kolmogrov-Smirnov test, descriptive statistics were conducted with frequencies and percentages for qualitative variables, measures of central tendency (mean, median) and of dispersion (interquartile ranges, standard deviation), and with comparison of the two therapeutic groups with Student's T-test or the Mann-Whitney U-test for quantitative variables and the Chi-squared test or Fisher's exact test for qualitative variables. The dependent variables (VAS, heart rate, respiratory rate, systolic and diastolic blood pressure) were compared in the two groups with different measures including the ANOVA repeated measures test or Friedman's test, depending on the distribution. A value of p < 0.05 was considered significant.
Results
From March 2012 to December 2013, 6880 births were attended of which 600 were eligible for this study. Losses and exclusions of patients are shown in Fig. 1.
The total population was 114 patients with 1 or more gestations, undergoing induction/conduction of labor, divided into two balanced groups of 57 women (bupivacaine at 0.125% and bupivacaine at 0.25%). The average age was 23.8 ± 4.6 years. The average weight was 64.5 ± 8 kg. The mean number of gestations was 1 (1-3). 70 (61%) were primiparous and 30 (26%) were induced births.
During the management of labor, 20 (16%) received oxy-tocics, and the median of centimeters of dilation was 4 both after (3-7) and before (3-9) analgesia. The latency time of the analgesic effect was S ± l. Smin and there were no complications reported (hypotension, inadvertent dural puncture, intravascular injection, motor blockade) during the procedure in any of the patients.
Upon comparing the bupivacaine at 0.125% group to the bupivacaine at 0.25% group, there were differences found only in the history of previous births: 20% of the first group against 3S% of the second group (p-value = 0.04) (Table 1).
Upon comparing the values of the visual analog scale (VAS) measured at 0, 1S, 30, 60 and 90 min (Table 2), statistically significant differences were found in favor of the group with bupivacaine at 0.25% with a reduction in pain perception starting at minute 30 (p-value = 0.02) (Fig. 2). No differences were found in systolic blood pressure, diastolic blood pressure, heart rate, or respiratory rate between the two groups.
Discussion
The current tendency in obstetric epidural analgesia is to use local anesthetics at the minimum effective concentration16 in order to reduce possible secondary effects to the mother and to the progress of labor17-19.
The safety and efficacy of bupivacaine compared to other anesthetics is known20. Nevertheless, the dose used varies depending on the study, with variations between 0.0125 and 0.37%21. The well-known risk is that labor may end in an instrumental delivery or with complications that affect the mother and the child22.
The results of this study demonstrate that, at two different concentrations of bupivacaine, no complications occurred and the only significant difference was in pain perception.
The general characteristics of the population are similar to those found in any second-level of care hospital that offers obstetric services. Thus, the external validity of the study is good.
There were no statistically significant differences between the two groups in terms of age, previous cesarean sections, the use of oxytocin, and the number of previous gestations and analgesia. Therefore, initially, the populations are homogenous. Kolmogorv-Smirnov p > 0.05.
Usually, bupivacaine is used in combination with other pharmaceuticals like fentanyl or meperidine, and it has been found that the higher the concentration, the higher the risk or instrumental delivery and prolonged labor23. Bupivacaine, compared to other pharmaceuticals used during labor, has safer results if it is used exclusively24,25, though user satisfaction may vary depending on dosage or combination26.
Previous studies, with less "blind" procedures and dependent variables other than pain, report that there are no differences in the concentration of bupivacaine27-29, which differs with our results.
Since the procedure was controlled under methodological rigor, this is a study of efficacy. The main evidence is that the perception of pain reported by the patient appears to be statistically less in those women that received a concentration of bupivacaine at 0.25%. Most remarkable is that there are no differences in the rest of the vital signs and in instrumental delivery.
Our study is innovative in that there are no published protocols with the same characteristics comparing bupiva-caine at different concentration levels. The results that we obtained suggest that, by using the 0.25% concentration, analgesic effectiveness can be increased without causing adverse effects. While the difference was not statistically significant, patients who received bupivacaine at 0.25% did not merit a second dose. We decided to not include those patients that merited three or more doses due to the probability of loosing the purity of the procedure (due to the lack of blindness from the anesthesiologist with respect to the concentration). Nevertheless, the application of three or more doses was greater in the group with 0.125% bupivacaine compared to the 0.25% group (8 vs 5).
The most pronounced weakness lies in that the dependent variable used, in this case VAS, is merely subjective and that this information is supplied entirely by the patient. For this reason, there may be a bias of poor classification and poor memory. This suggests that a study should be conducted comparing the most efficacious medication for treating pain in this kind of patient compared to the 0.25% concentration of bupivacaine. The methods and the limiting factor of not comparing it to other analgesics may limit its application in real clinical practice.
One of the adverse effects that may appear during epidural analgesia in labor is motor block produced by local anesthetics. This block may be the cause, in some cases, of a greater duration of the second stage of labor, greater incidence of instrumental deliveries and cesarean sections, and more discomfort for the mother30. With both concentrations, patient comfort is obtained without prolonging the second stage31-33. In our study, there were no significant differences found in terms of the presence of motor block.
Epidural bupivacaine provides excellent analgesia for labor and continues to be the most used local anesthetic in obstetric anesthesia34. The minimal local anesthetic concentrations (MLAC) have been used to determine the power of epidural analgesics like bupivacaine and its homologue levobupiva-caine, establishing that concentrations of bupivacaine at 0.125 and 0.25% have analgesic effect and are safe35.
Conclusion
Analgesic efficacy of bupivacaine at 0.25% concentration was better compared to bupivacaine at 0.125% concentration, with no associated complications such as difficulty walking, requirements of extra doses, or complications for the mother-child unit. The measurement of other variables of interest merits study to enrich the results.
Ethical disclosures
Protection of human and animal subjects. The authors declare that the procedures followed were in accordance with the regulations of the relevant clinical research ethics committee and with those of the Code of Ethics of the World Medical Association (Declaration of Helsinki).
Confidentiality of data. The authors declare that they have followed the protocols of their work center on the publication of patient data.
Right to privacy and informed consent. The authors have obtained the written informed consent of the patients or subjects mentioned in the article. The corresponding author is in possession of this document.
Funding
None.
Conflict of interest
The authors have no conflict of interests to declare.
References
1. Lally J, Murtagh M, Macphail S, Thomson R. More in hope than expectation: a systematic review of women's expectations and experience of pain relief in labour. BMC Med. 2008;6:7. [ Links ]
2. Reitman E, Conell-Price J, Evansmith J, Olson L, Drosinos S, Jasper N, et al. β2-Adrenergic receptor genotype and other variables that contribute to labor pain and progress. Anesthesiology. 2011;114:927. [ Links ]
3. Rivera-Diaz R, Lopera-Rivera A. Manejo del dolor no obstétrico durante el embarazo Artículo de revisión. Rev Colomb Anestesiol. 2012;40:213-23. [ Links ]
4. Howell CJ, Kidd C, Roberts W, Upton P, Lucking L, Jones PW, et al. A randomised controlled trial of epidural compared with non-epidural analgesia in labour. BJOG. 2001;108:27-33. [ Links ]
5. Williamson A, Hoggart B. Pain: a review of three commonly used pain rating scales. J Clin Nurs. 2005;14:798-804. [ Links ]
6. Gogarten W, Van Aken H. A century of regional analgesia in obstetrics. Anesth Analg. 2000;91:773-5. [ Links ]
7. Marucci M, Cinnella G, Perchiazzi G, Brienza N, Fiore T. Patient-requested neuraxial analgesia for labor: impact on rates of cesarean and instrumental vaginal delivery. Anesthesiology. 2007;106:1035-45. [ Links ]
8. Raja S, Meyer R, Campbell A. Peripheral mechanisms of somatic pain. Anesthesiology. 1988;68:571-90. [ Links ]
9. González-Cárdenas VH, Munar-González F, Gómez-Barajas W, Cardona MA, Rosero BR, Manrique AJ. Remifentanilo vs analgesia epidural para el manejo del dolor agudo relacionado con el trabajo de parto Revisión sistemática y meta-análisis. Rev Colomb Anestesiol. 2014;42:136-7. [ Links ]
10. Beilin Y, Guinn NR, Bernstein HH, Zahn J, Hossain S, Bodian CA. Local anesthetics and mode of delivery: bupivacaine versus ropivacaine versus levobupivacaine. Anesth Analg. 2007;105:756-63. [ Links ]
11. Zapata-Sudo G, Trachez MM, Sudo RT, Nelson TE. Is comparative cardiotoxicity of S(-) and R(+) bupivacaine related to enantiomer-selective inhibition of L-type Ca2+ channels? Anesth Analg. 2001;92:496-501. [ Links ]
12. Comparative Obstetric Mobile Epidural Trial (COMET) Study Group, UK. Effect of low- dose mobile versus traditional epidural techniques on mode of delivery: a randomized controlled trial. Lancet. 2001;358:19-23. [ Links ]
13. Kee WDN, Ng FF, Khaw KS, Lee A, Gin T. Determination and comparison of graded dose-response curves for epidural bupivacaine and ropivacaine for analgesia in laboring nulliparous women. Anesthesiology. 2010;113:445-53. [ Links ]
14. Sultan P, Murphy C, Halpern S, Carvalho B. The effect of low concentrations versus high concentrations of local anesthetics for labour analgesia on obstetric and anesthetic outcomes: a meta-analysis. Can J Anaesth. 2013;60:840-54. [ Links ]
15. Aguilar-Barojas S. Fórmulas para el cálculo de la muestra en investigaciones de salud. Salud en Tabasco. 2005;11:333-8. [ Links ]
16. Anim-Somuah M, Smyth R, Howell C. Epidural versus non-epidural or no analgesia in labour. Cochrane Database Syst Rev. 2011;7:CD000331. Disponible en: http://www.update-software.com/pdf/CD000331.pdf. [ Links ]
17. Shnider SM, Levinson G, Ralston D. Regional anesthesia for labor and deliver. In: Shnider SM, Levinson G, editors. Anesthesia for obstetrics. 3a ed. Baltimore: Williams and Wilkins; 1995. p. 135-53. [ Links ]
18. Chesnut DH, Laszewski LJ, Pollack K, Bates J, Manago NK, Choi W. Continuous epidural infusion of 0.0625% bupivacaine-0.0002% fentanil during the second stage of labor. Anesthesiology. 1990;72:613-8. [ Links ]
19. Gomar C, Fernández C. Epidural analgesia-anesthesia in obstetrics. Eur J Anaesthesiol. 2000;17:542-58. [ Links ]
20. Howell CJ, Dean T, Lucking L, Dziedzic K, Jones PW, Johanson RB. Randomised study off long term outcome after epidural versus non-epidural during labour. Obstet Gynecol. 2003;101:195-8. [ Links ]
21. Loughnan BA, Carli F, Romney M, Dore CJ, Gordon H. Randomized controlled comparision of bupivacaine versus pethidine for analgesia in labour. Br J Anaesth. 2000;84:715-9. [ Links ]
22. Halpern S, Breen T, Campbell DC, Blanchard W. Epidural PCA fentanyl/bupivacaine vs IV PCA fentanyl: neonatal effects. Anesthesiology. 1999;90:A119. [ Links ]
23. Stienstra R, Jonker TA, Bourdrez P, Kuijpers JC, Van Kleef JW, Lundberg U. Ropivacaine 0.25% versus bupivacaine 0.25% for continuous epidural analgesia in labor: a double-blinded comparison. Anesth Analg. 1995;80:285-9. [ Links ]
24. Owen MD, D'Angelo R, Gerancher JC, Thompson JM, Foss ML, Babb JD, et al. 0.125% ropivacaine is similar to 0.125% bupivacaine for labor analgesia using patient-controlled epidural infusion. Anesth Analg. 1998;86:527-31. [ Links ]
25. Eddleston JM, Holland JJ, Griffin RP, Corbett A, Horsman EL, Reynolds F. A double-blind comparison of 0.25% ropivacaine and 0.25% bupivacaine for extradural analgesia in labour. Br J Anaesth. 1996;76:66-71. [ Links ]
26. Meister GC, D'Angelo R, Owen M, Nelson KE, Gaver R. A comparison of epidural analgesia with 0.125% ropivacaine with fentanyl versus 0.125% bupivacaine with fentanyl during labour. Anesth Analg. 2000;90:632-7. [ Links ]
27. Lee BB, Ngan Kee WD, Ng FF, Lau TK, Wong ELY. Epidural infusions of ropivacaine and bupivacaine for labor analgesia: a randomized double-blind study of obstetric outcome. Anesth Analg. 2004;98:1145-52. [ Links ]
28. Polley LS, Columb MO, Naughton NN, Wagner DS, M. van de Ven CJ. Effect of epidural epinephrine on the minimum local analgesic concentration of epidural bupivacaine in labor. Anesthesiology. 2002;96:1123-8. [ Links ]
29. Scott DB, Lee A, Fagan D, Bowler GMR, Bloomfield P, Lundh R. Acute toxicity of ropivacaine compared with that of bupivacaine. Anesth Analg. 1989;69:563-9. [ Links ]
30. Segado-Jiménez MI, Arias-Delgado J, Domínguez-Hervella F, Casas-García ML, López-Pérez A, Izquierdo-Gutiérrez C. Analgesia epidural obstétrica: fallos y complicaciones neurológicas de la técnica. Rev Soc Esp Dolor. 2011;18: 276-82. [ Links ]
31. McCrae AF, Jozwiak H, McClure JH. Comparison of ropivacaine and bupivacaine in extradural analgesia for relief of pain in labour. Br J Anaesth. 1995;74:261-5. [ Links ]
32. Cohen S, Yeh J, Riley E, Vogel T. Walking with labor epidural analgesia. Anesthesiology. 2000;92:387-92. [ Links ]
33. Collis RE, Harding SA, Morgan BM. Effect of maternal ambulation on labour with low-dose combined spinal epidural analgesia. Anaesthesia. 1999;54:535-9. [ Links ]
34. Polley LS, Columb MO, Naughton NN, Wagner DS, van de Ven CJM. Relative analgesic potencies of ropivacaine and bupivacaine for epidural analgesia in labor: implications for therapeutic indexes. Anesthesiology. 1999;90:944-50. [ Links ]
35. Lacassie HJ, Columb MO. The relative motor blocking potencies of bupivacaine and levobupivacaine in labor. Anesth Analg. 2003;97:1509-13. [ Links ]