SciELO - Scientific Electronic Library Online

 
vol.21 issue43Technical-economic feasibility analysis of micro grids integrating fuel cells in non-interconnected zones in ColombiaDevelopment of a small-scale residential microgrid prototype author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

Related links

  • On index processCited by Google
  • Have no similar articlesSimilars in SciELO
  • On index processSimilars in Google

Share


TecnoLógicas

Print version ISSN 0123-7799On-line version ISSN 2256-5337

Abstract

MURILLO-YARCE, Duberney; MARULANDA-DURANGO, Jesser J.  and  ESCOBAR-MEJIA, Andrés. Estudio comparativo de técnicas PWM de banda de histéresis para el control de corriente en filtros activos de potencia paralelos. TecnoL. [online]. 2018, vol.21, n.43, pp.91-106. ISSN 0123-7799.  https://doi.org/10.22430/22565337.1058.

This paper evaluates the performance of an active power filter using three hysteresis band current control techniques: fixed-band, adaptive-band, and Space Vector Modulation. The characteristics of each method, along with their behaviour under different operating conditions, are studied by means of time domain simulations. The pq theory is used in all the cases to calculate the current reference, and a proportional controller is implemented to regulate the voltage in the dc bus. Based on the results, the PWM techniques evaluated in this work enable a reduction in the harmonic content of the supply grid currents that ranges from 31% without compensation to 6% after the active power filter is connected. The adaptive hysteresis band method exhibited the worst performance in the elimination of harmonics in grid currents; furthermore, it presented the largest reduction of variations in the switching frequency and requires more calculation time because the band width must be computed at each iteration. In turn, the fixed hysteresis band alternative is the most widely recommended for applications that involve parallel filters because it has a simpler structure that enables its implementation. Finally, the technique that combines space vector modulation and hysteresis band current control produced highly-variable switching frequencies and a more complex implementation.

Keywords : Active power filters; current control techniques; harmonic compensation; hysteresis band; vector modulation.

        · abstract in English | Spanish     · text in Spanish     · Spanish ( pdf )