Tecciencia

Print version ISSN 1909-3667

Tecciencia vol.9 no.17 Bogotá July/Dec. 2014

https://doi.org/10.18180/tecciencia.2014.17.3 

DOI: http://dx.doi.org/10.18180/tecciencia.2014.17.3

An estimation of the effective dose for the internal contamination of workers occupationally exposed to open sources of 131i in thyroid treatments

Una estimación de la dosis efectiva para la contaminación interna de trabajadores ocupacionalmente expuesto a abrir fuentes de 131I en tratamientos de tiroide

J.A. Lecuna1, L.I. Carrizales1, B.M. Dantas2

1 Instituto Venezolano de Investigaciones Científicas IVIC, Caracas, Venezuela, jj1211g@yahoo.com
2 Institutosde Radioproteção e Dosimetria-IRD, Rio de Janeiro, Brasil

How to cite: Lecuna, J. A. et al., An estimation of the effective dose for the internal contamination of workers occupationally exposed to open sources of 131I in thyroid treatment, TECCIENCIA, Vol. 9 No. 17., 23-28, 2014, , DOI: http://dx.doi.org/10.18180/tecciencia.2014.17.3

Received: 16/Aug/201 Accepted: 20/Sep/2014 Published: 30/Dec/2014


Abstract

Handling a variety of unsealed sources in Nuclear Medicine has led to a significant risk of internal exposure for workers. 131I stands out among the radionuclides of frequent use due to its wide application in diagnosis and treatment of thyroid diseases. This study presents the development of in vivo bioassay techniques, in order to quantify the incorporation of 131I used in nuclear medicine. It also presents the results of research related to the internal exposure of a group of workers involved in handling therapeutic doses of 131I. The in vivo detection system was calibrated with a thyroid phantom developed at IRD (Brazil) which is also used at the UTN-IVIC (Venezuela). The workers monitored in this study presented measurable intake. Therefore, it is important to ensure future monitoring of such exposure. It also gives us the possibility of evaluating intake in cases of suspected accidents. The highest estimated effective dose was 1,28x10-5 Sv by inhalation and 1,27x10-5 Sv by ingestion. The proposed method showed enough sensitivity for its application in the assessment of the effective dose for 131I intake by workers. The minimum detectable effective dose associated with the MDA (244 to 287 Bq) is three orders of magnitude below the recording level of 1 mSv, considering a single intake by inhalation of a Type F compound of 131I in the form of vapor.

Key words: Thyroid, iodine-131, Effective Dose, Internal Contamination.


Resumen

La manipulación de fuentes no selladas en Medicina Nuclear ha dado lugar a un riesgo significativo de exposición interna de los trabajadores. El 131I se destaca entre los radionucleidos de uso frecuente por su amplia aplicación en diagnóstico y tratamiento de enfermedades de tiroides. Este trabajo presenta el desarrollo de técnicas de bioensayos "in vivo", con el fin de cuantificar la incorporación de 131I utilizado en Medicina Nuclear. También se presentan los resultados de la investigación de la exposición interna de trabajadores involucrados en el manejo de dosis terapéuticas de 131I. El sistema de detección "in vivo" fue calibrado con el simulador de tiroides desarrollado en el IRD (Brasil) y con el cual cuenta la UTN-IVIC (Venezuela). Los trabajadores controlados en este estudio tuvieron resultados mensurables en cuanto a la incorporación, por lo cual, es menester establecer su control a futuro y también nos da la posibilidad de evaluar las incorporaciones en casos de sospecha de un accidente. La estimación de la dosis efectiva más alta fue 1,28x10-5 Sv por inhalación y 1,27x10-5 Sv por ingestión. El método propuesto mostró sensibilidad para su aplicación en la estimación de la dosis efectiva por incorporación de 131I en TOEs sobre la base de AMD calculado (mínimo 244Bq y máximo 287Bq), el cual se encuentra tres órdenes de magnitud por debajo del nivel máximo de 1mSv, considerando el escenario de incorporación único, compuesto en forma de vapor (tipo F) y la inhalación como la principal vía de entrada de 131I en el cuerpo.

Palabras clave: Tiroides, iodo-131, Dosis Efectiva, Contaminación Interna.


1. Introduction

Iodine-131 (131I) is a radionuclide of high radiotoxicity which is used in nuclear medicine, principally for the diagnosis and treatment of thyroid diseases (differentiated thyroid cancer and hyperthyroidism). 131I is a beta and gamma emitter with a decay half-life of 8.02 days. Activities employed in the practice fall between 3.7 and 111MBq (0.1-3mCi) for the evaluation of thyroid function, between 148 and 925MBq (4-25mCi) for the treatment of hyperthyroidism, and between 1110 and 7400MBq (30-200mCi) for differentiated thyroid cancer (DTC) [1].

It is therefore necessary, in order to have an impact at the national level here in Venezuela, to apply the country's Radiological Protection Program (Programa de Protección Radiológica) for all Iodine-131 treatment. This is done via the direct measurement of the activity incorporated into the thyroid of occupationally exposed workers [OEW], and the radiometric analysis of urine samples collected within 24 hours, in accordance with the recommendations proposed by the International Atomic Energy Agency (IAEA) in Safety Guide No. RS-G-1.2 [2]. The objective is to verify compliance with the primary limits established by Venezuelan legislation regarding occupationally exposed workers, and thus adopt a single procedure for the evaluation of occupational doses within an extensive routine program that monitors radiological exposure in Venezuela.

When estimating internal contamination in nuclear medicine services, an effective alternative for monitoring occupational exposure would be the utilization of thallium-activated sodium iodide crystal (NaI(Tl) 2"x2") detectors which, from previous calibrations, are converted into efficient body activity monitors which can be used to carry out measurements within the departments of nuclear medicine themselves. Hence, the potential unusual event of radionuclide intake (ie: 131I) in occupationally exposed individuals can be detected in advance, allowing for immediate action regarding the individual as well as the revision of procedures adopted for these aims. This allows the verification of compliance with current standards [2] concerning the radiation dose limit of workers and members of the public under normal working conditions.

Likewise, it permits the identification of an atypical contamination situation and the subsequent evaluation of its severity in order to determine appropriate corrective action.

The estimation of the committed effective dose is expressed as E(50)=∑wTHT(50), where wT are the tissue weighting factors and HT(50) is the equivalent dose with an integration time of 50 years [3]. This can be estimated via direct measurements of the whole body, organs, or wounds, or via indirect measurements, analyzing the presence of radionuclides in excreta or in the work environment.

The internal dosimetry evaluates the results of these direct and indirect measurements, taking into account factors such as the physical and chemical characteristics of the radioactive substances, the mode of intake, and the metabolic processes involved. For this, the biokinetic and dosimetric models recommended by international specialists, principally the ICRP [4], are interpreted and applied. Additionally, this aids in the elaboration of applicable monitoring plans at installations, as well as in obtaining specific Annual Limits on Intake (ALI) for a specific workplace.

This study was performed at the Nuclear Medicine Department of La Trinidad Teaching Medical Center (Servicio de Medicina Nuclear del Centro Medico Docente La Trinidad) in Caracas, Venezuela, and the dosimetry was performed on two OEWs without regard for age and gender.

2. Materials and methods

For the in vivo laboratory bioassay, the Venezuelan Institute for Scientific Research (IVIC) acquired, via the Radiological Protection and Dosimetry Institute (IRD) of Rio de Janeiro, a thyroid uptake neck phantom containing a 133Ba source of known activity. The total amount of activity (t = 134471 Bq/g (3,634 µCi/g)) from the 133Ba source was previously calibrated by Radionuclide Metrology services and sent in for preparation of the neck phantom.

The phantom, a thyroid simulator containing a known activity, was developed at IRD's In Vivo Measurement Laboratory [5]. The simulation of the thyroid was achieved by adding 200 mL of standard solution (133Ba) of known activity to filter paper, thus simulating the organ. It was properly sealed, then positioned and placed in the interior of the neck phantom in order to perform the measurements and calibrations.

Figure 1 shows the preparation sequence for the neck phantom, which was constructed by IRD under the project ARCAL LXXVII [6].

The detector consists of an assembly formed by a thallium-activated sodium iodide crystal (NaI(Tl) 2"x2") connected to a photomultiplier, a light guide, a voltage divider, a resistor divider, a dynode, and a preamplifier. The entire assembly is surrounded by 2.0cm-thick shielding. This detector can be used in conjunction with a mobile support model, which allows correct positioning relative to the occupationally exposed worker.

In order to ensure the reliability of the monitoring results, it is important to periodically perform a quality control check, evaluating parameters related to sensitivity, resolution, precision, and linearity, as well as to carry out measurements of the background or natural radiation [7].

Before the calibration of the detector with the neck phantom, the background radiation at the site was measured with a thyroid phantom. This phantom is an optimization of the original prototypes developed during the ARCAL project [6], which involved the calibration of the detectors with a thyroid phantom containing 133Ba (equivalent to 131I).

Additionally, a correction was performed on the effective dose calculations via the software AIDE v6.0. This tool and the routine acquisition of data allow us to attain a better view of the internal contamination that may be occurring within each OEW and thus to bestow adequate and timely attention upon them.

The neck phantom was then used for the calibration of the detector. It simulates the thyroid with an equivalent known activity of 131I (A = 25959 Bq), previously calibrated. The established measurement geometry was 20 cm from the face of the detector to the neck phantom.

A methodology for monitoring internal 131I contamination of OEWs has been established at the Nuclear Medicine Department of the La Trinidad Teaching Medical Center, being the only center in Caracas with the detector available at the time of study. Additionally, the results are presented in order to determine the intake and to estimate the effective dose for two OEWs involved in the handling of therapeutic doses of 131I. The handled activities were found to be in the range of 1,11x107 Bq and 5,55x109 Bq. The workers handled 131I activities in both liquid and capsule form.

The OEWs were selected in order to follow the steps of 131I intake and to estimate the committed effective dose via in vivo biassay procedures.

Interpretation of the Bioassay Data: using AIDE Software version 6.0 (Activity and Internal Dose).

The AIDE (Activity and Internal Dose Estimates) software [8] is a program for calculating the activity of the intake of radionuclides. At the same time, it provides an estimation of the effective dose, based on in vivo and in vitro bionalysis data, and is used specifically for OEWs who, in their daily activity, are subject to radionuclide intake, such at Nuclear Medicine departments.

The program allows the selection of biokinetic models associated with radioactive decay data, based on the elements enumerated in the ICRP 78 [9]. For the correct interpretation of the measurement results of the incorporated activity, which were performed through the in vivo and in vitro bioanalysis techniques, it is essential to take into account the volatility of 131I, information about the primary route of intake, the manner of intake, and the form of the compounds. For the specific case in our study, we consider an acute intake of 131I via inhalation, classified as a compound in vapor form.

Besides estimating the intake and the committed effective dose through in vivo and in vitro measurements, the use of AIDE also makes it possible to calculate the derived recording levels (DRL), taking into account the intake (Bq) that corresponds to an effective dose of 1 mSv in different time intervals.

To calculate the minimum detectable intake (I), we considered the relationship between the minimum detectable activity (MDA) of the technique and the function of retention or excretion of the correspondent behavior in which the measurement was carried out (the thyroid) for the pre-defined time interval, whose scenario for the interpretation of the relative data is a single intake. Under these circumstances, the effective dose (E) is calculated via the minimum detectable intake (I) and its dose coefficient (e(g)) of the radionuclides of interest (131I). The techniques presented to quantify the activity of incorporated 131I are applicable for routine individual monitoring, since the values found for the MDA of the monthly-measured frequency are below the annual maximum level of 1 mSv.

The detector is located in an area contiguous to the radiation area at the Nuclear Medicine Department at La Trinidad, where measurements for calibration are carried out. The calibration procedure was performed with the methodology employed by the IRD's in vivo Bionalysis Laboratory. It consists of placing the neck phantom on a base 1 meter from the floor, with the collimator flush and perpendicular to it. This separates the NaI (Tl) (2"x2") detector from the phantom at a distance of 20cm. We proceeded to take 5 measurements of the phantom directly and another 5 with the 3cm lead barrier, which is placed between the detector and the phantom to measure the background radiation. All of this is to calculate the decay in the activity of the phantom from manufacturing to the calibration of the detector [10], in accordance with the methodology.

3. Results y discussion

The values of the effective dose E(50) estimated by the measurements made with the detector for the weekly monitoring frequency (9.50 μSv for inhalation and 9.47 μSv for ingestion), based on the MDA value of 244 Bq, determined for 10 minutes of counts, in the geometry of the thyroid, demonstrate the applicability of the technique for the evaluation of 131I intake, since they are below the recording level of 1 mSv.

The obtained E(50) results, based on the MDA for 10 minutes of counts and using the (NaI (Tl) (2x2)) detector, demonstrate the applicability of the system for the evaluation of the intake of 131I by the OEWs, considering intake via inhalation, classified as type F in vapor form.

The different values of MDA were obtained with the portable (NaI (Tl) 2 "x 2") system for the calibration measurements with the phantom containing 133Ba. The lowest value of MDA was obtained when the calibration was performed in a room contiguous to the hot room, where the radiopharmaceuticals that are going to be administered are handled. It is worth mentioning that the lower the MDA, the greater the possibility of detection of incorporated radionuclides. The MDA establishes a detection minimum, from which the obtained measurement results are taken as positive.

With the obtained values in Table 1, the MDA is calculated, which is the minimum activity that was possible to detect in a volunteer that has not worked in areas where radiation is used. The criteria and conditions of measurement are the same as for the exposed workers.

Measurements were performed on the OEWs (see Table 2 and Table 3), whose results indicate the presence of small intakes arising from the handling of unsealed source of 131I. This confirms the importance of this routine monitoring - to ensure that workers are carrying out their responsibilities safely and that the staff adopt and comply with radioprotection procedures - and allows the projection of measurements for a year in the future, to see if they surpass the annual limits of 1 mSv of effective dose. Table 2 and Table 3 show that, regardless of the activity handled, an intake exists.

Date1 = Intake date; Date2 = Measurement date; T = Total cpm; B = Background cpm; N = Net cpm; AH = Activity handled; AT = Activity detected in thyroid

Taking the highest activity handled, we have a total of 424x106KBq annually and an activity detected in the thyroid of 243KBq and close to 0.8 mSv of annual effective dose. This assumes the administration of 131I once a week in different treatments, the same working conditions, and the same level of caution towards radiological protection.

The calibrations guarantee the reliability of the measurements, since by calculating the decay we know the exact activity in the thyroid phantom we are working with when measuring. Based on these measurements (Table 4) and by calculating the uncertainty, a value of ± 4% was obtained, which is acceptable given the quantity of measurements.

Source: 133Ba; Time: 10 minutes; Distance: 20cm from the detector to the neck; Date: 16/02/11.

Table 5 and 6 display the in vivo measured values of the thyroid for the workers. The proposed scenario for the evaluation of the E(50), based on the MDA technique, is as follows: single intake, via inhalation and ingestion, Type F 131I compound in vapor form.

For a better appreciation, the intake and effective dose E(50) by inhalation and ingestion for each OEW are represented graphically (Figures 2 and 3). This demonstrates the sensitivity of the proposed system, allowing us to guarantee the methodology of our study so that routine monitoring of the OEWs generates figures which aligned with the reality of the occurring internal contamination.

Time interval: 24 hours; m(t) inhalation: 2,29x10-1Bq; e(g) inhalation: 1,98x10-8Sv/Bq; m(t) ingestion: 2,25x10-1Bq; and e(g) ingestion: 2,17x10-8Sv/Bq. DateE = Date de exposure; AT = Activity detected in the thyroid; MDA = Minimum Detectable Activity; Iinh = Intake by inhalation; Iing = Intake by ingestion

The low observed doses in this small group, with the measureable existence of intake, indicate the importance of continued monitoring of intake and give the possibility of evaluating the intakes in cases of suspected accidents.

As seen in Figures 2 and 3, there is no significant difference in the dose estimation when comparing the two routes of intake (inhalation or ingestion). Additionally, a calculation of tendencies was performed to determine how close the data are among themselves and the R2=1 in the four effective dose estimations for both inhalation and ingestion in the two OEWs. It indicates that the correspondence between the effective dose E(50) and the activity measured in the thyroid is linear - at greater activities there is a greater effective dose E(50), providing the principles of radiological protection are not followed.

4. Conclusions

The Secondary Laboratory of Dosimetric Calibration at the IVIC can perform a trial to carry out the calibrations of the in vivo systems via its neck phantom and instruct nuclear medicine services staff to perform the conversion of 133Ba to 131I. The proposed method showed sensitivity for its application in our monitoring as values estimated over a base of calculated MDA (244Bq minimum and 287Bq maximum). It is three orders of magnitude below the maximum level of 1 mSv, considering a scenario of a single intake, a compound in vapor form (Type F), and inhalation as the principal route of entry of the 131I into the body.

The sensitivity of the detector permitted the detection of small quantities (144.10 Bq) of intake in the two OEWs, whose routine procedures included the use of open sources of 131I with therapeutic purposes. The range of handled activity falls between 11 MBq and 7500 MBq (0.3 mCi and 203 mCi), while the findings of incorporated activity fall between 825 Bq and 4750 Bq.

Based on the minimum and maximum values of the activity measured through in vivo bioanalysis, estimations of the effective dose were approximately 3x10-6Sv - 20x10-6Sv for inhalation and 3x10-6Sv - 20x10-6Sv for ingestion, which indicates a measurable figure that is below the effective dose threshold of 1 mSv.


5. References

[1] A. Rodríguez, E. Estrada, M. Brandan y L. Medina, « Vigilancia de incorporaciones de 131I y estimación de dosis efectiva comprometida en el personal de un servicio de medicina nuclear.,» Revista de Fisica medica , vol. 11, n°; 1, pp. 43-54, 2010.         [ Links ]

[2] Organismo Internacional de energía atómica, «Evaluación de la exposición ocupacional debida a incorporaciones de radionúclidos. Colección de Normas de Seguridad de la OIEA. Guía de seguridad N° RS-G-1.2,» Viena, 2004.         [ Links ]

[3] ORGANISMO INTERNACIONAL DE ENERGÍA ATÓMICA., «Normas Básicas Internacionales de Seguridad para la protección de Radiaciones Ionizantes y para la Seguridad de Fuentes de Radiación. Colección de Seguridad N° 115.,» Viena, 1997.         [ Links ]

[4] International Commission on Radiological Protection., Human Respiratory Tract Model for Radiological Protection. ICRP Publication 66, Annals of the ICRP 25., Oxford: Pergamon Press, 1994.         [ Links ]

[5] B. Maranhao Dantas, «Bases para a Calibração de Contadores de Corpo Inteiro Utilizando simuladores físicos antropomorficos,» Instituto de biologia Roberto alcantara gomes. Departamento de Biofisica e Biometria, Rio de Janeiro, 1998.         [ Links ]

[6] Organismo Internacional de Energía Atomica OIEA, «Proyecto ARCAL 011. Armonización de Procedimientos de Dosimetría Interna,» Rio de Jaineiro, 2003.         [ Links ]

[7] M. Vidal, «Proposta de um modelo para monitoração ocupacional da contaminação interna por 131I em trabalhadores de Serviços de Medicina Nuclear. Dissertação de Mestrado.,» Instituto de Radioproteção e Dosimetria., Rio de Janeiro, 2004.         [ Links ]

[8] L. Bertelli, D. R. Melo, J. Lipztein y R. Cruz- Suarez, «AIDE: internal dosimetry software.,» Radiation Protection Dosimetry, vol. 130, n°; 3, pp. 358-367, 2008.         [ Links ]

[9] ICRP, «Individual monitoring for internal exposure of workers (Preface and glosary missing),» ICRP Publications 78, 1997.         [ Links ]

[10] E. Lucena, «Proposta de aplicação de técnicas de bioanálise "in vivo" e "in vitro" para avaliação da incorporação de 131I por trabalhadores de medicina nuclear. Tesis doctoral.,» Universidade Federal do Rio de Janeiro. , Rio de Janeiro, 2008.         [ Links ]